| Application | Recommended Sizing ( microns) |
Comments |
| Cooling Tower Bleed-off / Blowd | 5-55 | |
| Closed loop filtration | 5-55 | |
| Tower Basin Cleaning / Sweeper Jet | 5-55 | |
| Cartridge replacement | 2-55 | |
| Protection of Heat exchangers | 5-55 | Consult with manufacturer |
| Invasive Species | 40-70 | For larva removal |
| Membrane Protection | 70-300 | |
| Coal Ash | 20-50 | depends on process treatment train |
| Model | 4” x (4) x 10” | 4” x (5) x 10” | 4” x (6) x 12” | 4” x (7) x 12” | 4” x (8) x 12” |
| General Specifications | |||||
| Max. filtration flow rate* | 800 gpm | 1,000 gpm | 1,200 gpm | 1,400 gpm | 1,600 gpm |
| Backwash flow rate | 250 gpm | ||||
| Filter pump HP | 20 | 30 | |||
| BW booster pump HP | 15 | ||||
| Filter face pipe (flange) | 10” | 12” | |||
| Flush line (flange) | 4” | ||||
| Backwash water volume per cycle (gallons) |
~ 333 | ~ 417 | ~ 500 | ~ 583 | ~ 667 |
| Dry weight horiz / vert (lbs.) |
2,913 | 3,240 | 4,158 | 4,187 | 4,377 |
| *Flow is based on 55 μ filtration degree (Green discs) at Max TSS of 35 PPM | |||||